1. 輸油管道管道布(bu)置一般要求:
①. 輸(shu)油(you)管道應(ying)采用地下埋設(she)方(fang)式。當受自然條件限制時(shi),局部(bu)地段可采用土堤埋設(she)或地上(shang)敷設(she)。
②. 當輸(shu)油管道采取土(tu)堤(di)埋設時,土(tu)堤(di)設計應(ying)符(fu)合下列規定:
a. 輸油管(guan)道在土(tu)堤中的徑(jing)向覆土(tu)厚(hou)度(du)不應小(xiao)于(yu)1.0m;土(tu)堤頂寬應大(da)于(yu)管(guan)道直徑(jing)兩倍且不得小(xiao)于(yu)1.0m;
b. 土堤(di)(di)邊坡坡度(du)應根(gen)據當地自(zi)然條件(jian)、填土類別(bie)和(he)土堤(di)(di)高度(du)確定。對黏性(xing)土土堤(di)(di),堤(di)(di)高小于2.0m時,土堤(di)(di)邊坡坡度(du)可(ke)(ke)采用(1:0.75(1:0.75)~(1:1);堤(di)(di)高為2~5m時,可(ke)(ke)采取(1:1.25)~(1:1.5);
c. 土(tu)堤受水(shui)浸淹部分的邊坡(po)應(ying)采(cai)用(yong)1:2的坡(po)度,并應(ying)根據(ju)水(shui)流情況采(cai)取保(bao)護措施;
d. 在沼澤(ze)和低洼地區(qu),土堤的(de)堤肩高(gao)度應根據常水位、波浪高(gao)度和地基(ji)強度確(que)定;
e. 當土堤(di)阻擋水(shui)(shui)(shui)流(liu)排泄時(shi),應設置(zhi)泄水(shui)(shui)(shui)孔或(huo)涵洞等構筑物;泄水(shui)(shui)(shui)能力應滿足重現(xian)期為25年(nian)一遇的(de)洪(hong)水(shui)(shui)(shui)流(liu)量(liang);
f. 軟(ruan)弱地基(ji)上的土堤,應防止填土后基(ji)礎(chu)的沉陷;
g. 土(tu)堤(di)用土(tu)的(de)透水性能宜接(jie)近原狀土(tu),且應滿足填(tian)方的(de)強度和穩定性的(de)要求。
③. 地上敷設的(de)輸油(you)管道(dao)應采取措(cuo)施補(bu)償管道(dao)軸向變形。
④. 埋地(di)(di)管道的(de)埋設深度(du),應根(gen)據管道所經地(di)(di)段的(de)農田(tian)耕作深度(du)、凍土深度(du)、地(di)(di)形和(he)地(di)(di)質條件、地(di)(di)下水深度(du)、地(di)(di)面車輛所施加的(de)載(zai)荷(he)及管道穩定(ding)(ding)性(xing)的(de)要求等因素,經綜合分析后確定(ding)(ding)。管頂的(de)覆土層厚(hou)度(du)不宜小于0.8m。
⑤. 當(dang)埋地(di)輸油管(guan)(guan)道(dao)同其(qi)他(ta)埋地(di)管(guan)(guan)道(dao)或金屬構筑物交叉時(shi),其(qi)垂直(zhi)凈(jing)距不(bu)應小(xiao)(xiao)于(yu)(yu)0.3m,兩條管(guan)(guan)道(dao)的交叉角不(bu)宜小(xiao)(xiao)于(yu)(yu)30°;管(guan)(guan)道(dao)與(yu)電力、通信電纜交叉時(shi),其(qi)垂直(zhi)凈(jing)距不(bu)應小(xiao)(xiao)于(yu)(yu)0.5m。
⑥. 輸(shu)油(you)(you)管道(dao)通過(guo)人工(gong)或天然障礙物(水域、沖溝、鐵路、公(gong)(gong)路等)時(shi),應(ying)符合現行國家標(biao)準GB 50423《油(you)(you)氣(qi)輸(shu)送管道(dao)穿(chuan)越工(gong)程設(she)計規范》和GB 50459《油(you)(you)氣(qi)輸(shu)送管道(dao)跨(kua)越工(gong)程設(she)計規范》的有(you)關(guan)規定(ding)。液(ye)化石(shi)油(you)(you)氣(qi)管道(dao)穿(chuan)越鐵路、公(gong)(gong)路管段的設(she)計系數應(ying)按(an)國家現行標(biao)準GB50253《輸(shu)油(you)(you)管道(dao)工(gong)程設(she)計規范》。
⑦. 管(guan)(guan)(guan)溝(gou)(gou)溝(gou)(gou)底寬(kuan)度(du)應根(gen)據管(guan)(guan)(guan)溝(gou)(gou)深(shen)度(du)、鋼管(guan)(guan)(guan)的結構(gou)外徑及采(cai)取的施工(gong)措施確定。其管(guan)(guan)(guan)溝(gou)(gou)溝(gou)(gou)底寬(kuan)度(du)邊坡坡度(du)及管(guan)(guan)(guan)溝(gou)(gou)回填土作業應符合現(xian)行(xing)國(guo)家標準GB 50253中(zhong)的規定。管(guan)(guan)(guan)溝(gou)(gou)回填土后,應恢復原地貌,并保護(hu)耕植層,防止水(shui)土流失和積水(shui)。
⑧. 當埋地(di)輸油管(guan)道(dao)通過地(di)面(mian)坡度(du)大于18%的(de)地(di)段時(shi),應采取防止地(di)面(mian)徑流和滲水侵蝕和土體滑動影響(xiang)管(guan)道(dao)安全(quan)的(de)措施。
⑨. 當輸(shu)油管道(dao)穿越沖溝(gou),或管道(dao)一側鄰近(jin)發育中的(de)沖溝(gou)或陡坎時,應(ying)對沖溝(gou)的(de)邊(bian)坡和溝(gou)底(di)、陡坎采取加(jia)固措施。
2. 輸油管道需改(gai)變(bian)平面走向一(yi)般要求:
當輸油管(guan)(guan)道能改(gai)變平(ping)面(mian)走(zou)向(xiang)或(huo)為適應(ying)地(di)形(xing)變化改(gai)變縱(zong)向(xiang)坡度時,可(ke)采用(yong)彈性(xing)彎(wan)(wan)(wan)(wan)(wan)曲、冷(leng)彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan)和熱(re)煨彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan),不得采用(yong)蝦米腰彎(wan)(wan)(wan)(wan)(wan)頭(tou)或(huo)褶皺彎(wan)(wan)(wan)(wan)(wan)頭(tou)。在平(ping)面(mian)轉角較小(xiao)或(huo)地(di)形(xing)起伏不大的(de)情(qing)況(kuang)下,應(ying)優(you)先采用(yong)彈性(xing)彎(wan)(wan)(wan)(wan)(wan)曲敷設。當采用(yong)熱(re)煨彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan)時,其曲率半(ban)(ban)徑(jing)不宜小(xiao)于5倍管(guan)(guan)子(zi)外直(zhi)徑(jing),且應(ying)滿足(zu)清管(guan)(guan)器或(huo)檢測器順利通過的(de)要求。當采用(yong)冷(leng)彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan)改(gai)變平(ping)面(mian)走(zou)向(xiang)或(huo)縱(zong)向(xiang)披度時,冷(leng)彎(wan)(wan)(wan)(wan)(wan)彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan)的(de)最小(xiao)彎(wan)(wan)(wan)(wan)(wan)管(guan)(guan)半(ban)(ban)徑(jing)應(ying)符合表9.3.2的(de)規定。
3. 輸油管道采用彈性敷設的一般(ban)要求(qiu)。
在平面(mian)轉角較(jiao)小或(huo)地形起伏不(bu)大的(de)情況下,應(ying)優先采用(yong)彈性彎曲(qu)敷(fu)設(she)。
①. 彈性(xing)敷(fu)設管(guan)道的曲(qu)(qu)(qu)率(lv)(lv)半(ban)徑(jing)(jing)應(ying)滿足(zu)鋼管(guan)強度(du)要求,且不宜小于鋼管(guan)外直徑(jing)(jing)的1000倍(bei)。豎(shu)向(xiang)下(xia)凹的彈性(xing)彎曲(qu)(qu)(qu)管(guan)段,其曲(qu)(qu)(qu)率(lv)(lv)半(ban)徑(jing)(jing)尚應(ying)大于管(guan)道在自重(zhong)條(tiao)件下(xia)產(chan)生的撓(nao)度(du)曲(qu)(qu)(qu)線(xian)的曲(qu)(qu)(qu)率(lv)(lv)半(ban)徑(jing)(jing),其曲(qu)(qu)(qu)率(lv)(lv)半(ban)徑(jing)(jing)應(ying)按式(shi)(9.3.1)計(ji)算:
②. 彈性(xing)敷(fu)設管(guan)(guan)道與相鄰的反向彈性(xing)彎曲(qu)管(guan)(guan)段(duan)之間及彈性(xing)彎曲(qu)管(guan)(guan)段(duan)與彎管(guan)(guan)之間,應采用(yong)直管(guan)(guan)段(duan)連接,直管(guan)(guan)段(duan)長度(du)不應小于鋼管(guan)(guan)的外徑,且不應小于0.5m。
4. 輸油管道地上布置的一(yi)般要求。
①. 應采取補償管道縱向變形的措施;
②. 輸油(you)管(guan)道跨越道路、鐵路的凈空高度應符合(he)表(biao)9.3.3的規(gui)定。
③. 地上管道沿(yan)山坡敷設時,應采取防止管道下滑(hua)的措(cuo)施。
④. 對于需要(yao)保(bao)溫的(de)管道應(ying)考慮保(bao)溫措施。
5. 當(dang)埋(mai)地輸(shu)油管(guan)(guan)(guan)道同其他埋(mai)地管(guan)(guan)(guan)道或金屬構(gou)筑(zhu)物交叉(cha)(cha)時,其垂(chui)直凈距不(bu)應小(xiao)于0.3m;管(guan)(guan)(guan)道與電(dian)(dian)力(li)、通(tong)信電(dian)(dian)纜交叉(cha)(cha)時,其垂(chui)直凈距不(bu)應小(xiao)于0.5m;并應在(zai)交叉(cha)(cha)點處(chu)輸(shu)油管(guan)(guan)(guan)道兩側各10m以上的(de)管(guan)(guan)(guan)段和電(dian)(dian)纜采用(yong)相應的(de)最(zui)高絕(jue)緣等級防(fang)腐(fu)層(ceng)。
6. 當輸油管道通過雜散電流干擾區時,應按國家現行標準SY0007和SY/T 0017的有關規定采取防護措施。
7. 輸油管道的防腐蝕設計,應符合國家現行標準SY 0007、SY/T 0036和SY/T 0019的規定。輸油管道保溫層的結構應由防腐層、隔熱層和保護層組成。隔熱層的厚度應根據工藝要求并經綜合技術經濟比較后確定。